BASIC CONSTRUCTION OF AIR HEATER




The resistance wire inside the air heater is star wound formation.  This formation is used to moving air.  The offset coils increase/induce turbulent flow.  This allows the flowing air to have better contact with the heater surface, resulting in a more efficient heat transfer.





Controller for Air Heater






Testing Data




Other Air Heater Dimensions



SPECIAL CAUTIONS

The air flow MUST be given PRIOR to activation of the heater, and MUST be stopped AFTER cutting electricity (minimum 20 minutes of cooling time).  This should be strictly monitored.

Due to consideration shall be paid to keep the temperature at the heater tail under 200℃.

Use an oil and water separator. The air/gas MUST be clean all the time.


No warranty shall attach to all consumable parts (including the heater element), therefore, you are requested to observe the above condition.


A. 220V 850W, lead wires: 300 mm

B. 110V or 220V, lead wires: 300 mm, 200 W, 350 W, 450 W and 550 W, optional built-in thermocouple

C. 220V 850W, lead wires: 300 mm, optional built-in thermocouple

D. 220V 2000W, lead wires: 300 mm, optional built-in thermocouple

E. 220V 800W, lead wires: 1000 mm, optional built-in thermocouple